Solvers/

Pipe Flow & Darcy-Weisbach Pressure Drop

CAE WORKSTATIONDarcy-Weisbach (ISO 5167)Hydraulic Institute (HIS)

Deterministic engineering intelligence platform for mechanical, structural, and electrical designers. Standard-referenced calculation engines, 3D CAD workspace, and transparent engineering equations.

Loading...
▸Formula · assumptions · example(Darcy-Weisbach (ISO 5167) · Hydraulic Institute (HIS) · Crane Technical Paper 410)

Formula

Q=A⋅v,Re=ρvDμ,Δp=fLDρv22,hf=ΔpρgQ = A \cdot v, \quad \text{Re} = \frac{\rho v D}{\mu}, \quad \Delta p = f \frac{L}{D} \frac{\rho v^2}{2}, \quad h_f = \frac{\Delta p}{\rho g}

Continuity equation, Reynolds number regime classification (laminar Re < 2300, transition 2300-4000, turbulent Re > 4000), and Darcy-Weisbach frictional head/pressure loss.

Assumptions

  • · Incompressible Newtonian fluid flow with constant physical density ρ and dynamic viscosity μ
  • · Laminar regime strictly Re < 2300 governed by Hagen-Poiseuille analytical solution: f = 64 / Re
  • · Turbulent regime Re > 4000 governed by implicit Colebrook-White equation or explicit Haaland / Swamee-Jain approximation based on pipe relative roughness ε/D
  • · Critical transition zone (2300 ≤ Re ≤ 4000): Flow alternates intermittently between laminar bursts and turbulent eddies; solver applies conservative turbulent envelope to avoid non-physical pressure drop underestimation
REFERENCE WORKED EXAMPLE · TEXTBOOK BASELINE (NOT LIVE INPUT)
Crane TP 410 / ISO 5167 / Hydraulic Institute

Industrial Water Piping Darcy-Weisbach Friction Loss (DN50 Steel)

BASELINE STATUS: PASS(Deterministic Darcy-Weisbach solution verified)

Determination of Reynolds regime, Darcy friction factor f, and total hydrodynamic pressure drop for pumped water at 20 °C.

1. Inputs & Boundary Parameters
Internal pipe diameter D50.0 mm
Total pipe length L100.0 m
Mean flow velocity v1.80 m/s
Fluid density ρ (water @ 20°C)998.2 kg/m³
Dynamic viscosity μ1.002e-3 Pa·s
Absolute wall roughness ε (commercial steel)0.045 mm
2. Applied Governing Equations & Standards
Reynolds Number:
Re=(ρ⋅v⋅D)/μRe = (ρ · v · D) / μ
Regime Boundary Check
Relative Roughness:
ε/Dε / D
Moody Parameter
Darcy Friction Factor (Turbulent):
1/√f=−1.8⋅log10[(ε/(3.7⋅D))1.11+6.9/Re]1/√f = -1.8 · log10[ (ε/(3.7·D))^1.11 + 6.9/Re ]
Haaland Equation
Darcy-Weisbach Pressure Loss:
Δp=f⋅(L/D)⋅(ρ⋅v2/2)Δp = f · (L / D) · (ρ · v² / 2)
Crane TP 410 Eq. 1-4
Head Loss:
hf=Δp/(ρ⋅g)hf = Δp / (ρ · g)
Hydraulic Head
3. Intermediate Calculation Stages
Volumetric flow rate Q3.53
Reynolds number Re89,660
Relative pipe roughness ε/D0.00090
Darcy friction factor f0.0218
4. Reference Benchmark Verification & Acceptance ThresholdBENCHMARK: PASS
Frictional Pressure Drop Δp & Head Loss hf: Δp = 70.5 kPa (0.705 bar) | hf = 7.20 m
Acceptance limit: Re = 89,660 > 4000 (Turbulent, well outside unstable 2300-4000 transition zone)