Deterministic engineering intelligence platform for mechanical, structural, and electrical designers. Standard-referenced calculation engines, 3D CAD workspace, and transparent engineering equations.
Nb,Rd (EC3)
54.55 kN
χ 0.330 · λ̄ 1.609
φc·Pn (AISC)
50.4 kN
Fcr 79.6 MPa
Ncr (Euler)
63.85 kN
σcr 90.7 MPa
Safety vs. Nk
1.60
Elastic (Euler) buckling
Flexural buckling(N_Ed / N_b,Rd)
EN 1993-1-1 (6.46)73.3%
N_Ed: 40 kN
N_b,Rd: 54.55 kN
AISC 360-16 E3 (LRFD)(Pu / φc·Pn)
AISC 360-16 E379.4%
Pu: 40 kN
φc·Pn: 50.4 kN
Column & first buckling mode
- A
- 703.7 mm²
- Imin
- 27.73 cm⁴
- i
- 19.85 mm
- λ
- 151.1
- λ₁
- 93.9
Buckling curves σ–λ
Method comparison
| Method | σ (MPa) | N (kN) | N_Ed / N | Note |
|---|---|---|---|---|
| EN 1993-1-1 (curve a) | 77.5 | 54.55 | 73.3% | design resistance, γM1 incl. |
| AISC 360-16 φc·Pn | 71.6 | 50.4 | 79.4% | φc = 0.90 |
| Euler Ncr | 90.7 | 63.85 | 62.6% | elastic, perfect column |
| Tetmajer | 137.7 | 96.9 | 41.3% | out of range (λ > 104) — use Euler |
| Johnson | – | – | – | λ > Cc = 132.8 — Euler governs |
| Squash A·fy | 235 | 165.37 | 24.2% | upper bound |
Flexural buckling about the weak axis only. Torsional / flexural-torsional buckling (open sections), local buckling (class 4) and second-order effects from eccentric loads are not included.